CIRS 013乳腺模體,CIRS 013模體詳細介紹:
CIRS 013乳腺模體,CIRS 013模體描述
CIRS立體定向針活組織檢查培訓模型是一種一次性使用的培訓工具和乳腺攝影針活檢程序的實踐培訓?;糜耙部勺鳛榱Ⅲw定向系統(tǒng)的優(yōu)質(zhì)質(zhì)量保證裝置,每當安裝或修理新系統(tǒng)時都應使用,以確保精確定位針頭。在美國放射學會立體定向乳房活檢鑒定項目中,幻像可以用來進行定位精確度測試。
嵌入的致密物質(zhì)和微鈣化物的大小各不相同,并且被著色以易于視覺化。質(zhì)量和鈣化可以多次活檢。
CIRS 013乳腺模體的身體被塑造成代表部分壓縮的乳房。CIRS 013乳腺模體由專有凝膠制成,具有類似于人體組織的物理一致性,被彈性皮膚狀的膜包圍。材料很容易被壓縮以獲得最佳成像。
CIRS Model 013 Stereotactic Needle Biopsy Training Phantom提供了一個簡單的乳腺攝影針活檢程序培訓解決方案。
CIRS 013乳腺模體特征:
可壓縮
刺破時不會泄漏
包含各種大小密集的活體組織
包含用于可視化和活組織檢查的鈣化簇
擬人化的形狀準確模擬乳房的壓縮
模擬針的阻力
物理一致性與人體組織相似
兼容獨立和附加立體定位活檢系統(tǒng)
適用于數(shù)字系統(tǒng)
DESCRIPTION
A tissue equivalent, compressible biopsy training phantom, that wont leak!
Features:
Compressible
Does not leak when punctured
Contains various sizes of dense masses for biopsy
Contains calcification cluster for visualization and biopsy
Anthropomorphic shape for accurate simulation of breast compression
Simulated needle resistance
Palpable lesions
Physical consistency similar to human tissue
Compatible with both stand alone and add-on stereotactic biopsy systems
Country of Origin: United States of America
Stereotactic Needle Biopsy Training Phantom is a disposable training tool and practice medium for mammographic needle biopsy procedures. The phantom also serves as an excellent quality assurance device for stereotactic systems and should be used whenever a new system is installed or repaired to insure accurate needle placement. The phantom can be used to perform the localization accuracy test in the American College of Radiology's stereotactic breast biopsy accreditation program.
The phantom body is shaped to represent a partially compressed breast. This allows the user to easily compress the breast to 4.5 cm thickness for optimum imaging. The shape also enables the phantom to be used in systems where the patient is either prone or sitting. The phantom is made from a proprietary gel with a physical consistency similar to human tissue and, since the gel is a non-flowing material, it won't leak out when punctured. The gel is surrounded by an elastic skin-like membrane, which enables palpation of the embedded masses and provides needle resistance.
Embedded within the phantom are numerous solid masses in a range of sizes. These radiographically visible masses can be biopsied multiple times. The masses are colored black for easy visualization of a successful biopsy. These solid masses are randomly positioned so each phantom provides a unique training experience. Two calcification clusters are positioned within the medial transverse plane at the right and left edge of the phantom. These calcifications can be biopsied or used for QA checks on the mammography system. To aid in visualizing the location of the calcifications, the two groups are each clustered around a white but radiographically transparent mass.
The stereotactic training phantom offers an easy, low cost option to create a relaxed learning environment. The phantom can be reused multiple times with no special storage requirements.